{"_buckets": {"deposit": "af32fed6-87ba-43d7-bda4-f01242fe15f8"}, "_deposit": {"created_by": 12, "id": "2000043", "owner": "12", "owners": [12], "owners_ext": {"displayname": "tbgu_lib", "username": "tbgu2121"}, "pid": {"revision_id": 0, "type": "depid", "value": "2000043"}, "status": "published"}, "_oai": {"id": "oai:tbgu.repo.nii.ac.jp:02000043", "sets": ["1711512520413"]}, "author_link": [], "control_number": "2000043", "item_10002_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2024-03-31", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "19", "bibliographicPageStart": "13", "bibliographicVolumeNumber": "20", "bibliographic_titles": [{"bibliographic_title": "東北文化学園大学医療福祉学部リハビリテーション学科紀要 : リハビリテーション科学", "bibliographic_titleLang": "ja"}, {"bibliographic_title": "Rehabilitation science : memoirs of the Tohoku Bunka Gakuen University Faculty of Medical Science \u0026 Welfare, Department of Rehabilitation", "bibliographic_titleLang": "en"}]}]}, "item_10002_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "【目的】黄色着色フィルム使用の有無による短(S)・中(M)・長波長感受性(L)錐体コントラスト感度の客観的な変化をColorDx CCT-HD を用いて明らかにすることを目的とした.【対象および方法】屈折異常以外の眼疾患のない10 例18 眼(20.9±0.3 歳,矯正視力1.0 以上)を対象とした.黄色着色フィルムはペーパー・インクリボンCK900L を使用し,錐体コントラスト感度はColorDx CCT-HD を用いた.黄色着色フィルムで呈示視標を覆った状態(On)と通常測定状態(Normal)で左右眼をそれぞれ測定し,ColorDx CCT-HD の測定結果であるlogCS と独自Score の平均値を比較検討した.【結果】logCS はL・M・S 錐体において,Normal でそれぞれ2.0±0.1,1.9±0.1,0.8±0.1,On で1.9±0.1,1.9±0.1,0.6±0.1 となり,L,M 錐体は有意差がみられず,S 錐体で有意に低下した.Score の結果はNormalで106.2±14.1,103.3±11.9,99.3±13.9,On では99.7±12.4,96.1±9.1,77.9±11.3 で,logCS と同様だった.【結論】ColorDx CCT-HD で黄色着色フィルム使用の有無による錐体コントラスト感度測定をした結果,S 錐体コントラスト感度の有意な低下がみられ,S 錐体活動の抑制を客観的に示すことができた.", "subitem_description_language": "ja", "subitem_description_type": "Abstract"}, {"subitem_description": "【Purpose】To investigate objective changes in long (L), middle (M), and short wavelength sensitive (S) cones contrast sensitivity with and without using a yellow tinted film.【Subjects and methods】The subjects were 18 eyes (20.9±0.3 years old, corrected visual acuity of 1.0 or more in decimal) of 10 patients with no eye disease other than refractive error. The film used was a paper ink ribbon. The cone contrast sensitivity (CCS) was measured using the ColorDx CCT HD software for color vision test. We used the Landolt ring corresponding to the L, M, and S cones. The measurements were recorded with the film non-covering target (Normal) and the covering target (On). We compared the logCS values and scores of each CCS with and without the film. 【Results】Regarding the L, M, and S cones, the logCS values were 2.0 ±0.1, 1.9±0.1, and 0.8±0.1 without the film and 1.9±0.1, 1.9±0.1, and 0.6±0.1 with it. No significant difference was observed under the L and M cones. The S cone significantly reduced. The scores were 106.2±14.1,103.3±11.9, and 99.3±13.9 without the film and 99.7±12.4,96.1±9.1 and 77.9±11.3 with it, similar to the logCS values. 【Conclusion】Measurements with of CCS with the ColorDx CCT-HD showed that the sensitivity of S-CCS using the film significantly reduced in young adult humans, objectively demonstrating suppression of the S cone activity.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10002_full_name_3": {"attribute_name": "著者(英)", "attribute_value_mlt": [{"names": [{"name": "Shota, Haraguchi", "nameLang": "en"}]}, {"names": [{"name": "Mineko, Ono", "nameLang": "en"}]}, {"names": [{"name": "Natsumi, Ishikawa", "nameLang": "en"}]}]}, "item_10002_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "東北文化学園大学医療福祉学部リハビリテーション学科", "subitem_publisher_language": "ja"}]}, "item_10002_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12032779", "subitem_source_identifier_type": "NCID"}]}, "item_10002_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "13497197", "subitem_source_identifier_type": "PISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "原口, 翔太", "creatorNameLang": "ja"}, {"creatorName": "ハラグチ, ショウタ", "creatorNameLang": "ja-Kana"}]}, {"creatorNames": [{"creatorName": "小野, 峰子", "creatorNameLang": "ja"}, {"creatorName": "オノ, ミネコ", "creatorNameLang": "ja-Kana"}]}, {"creatorNames": [{"creatorName": "石川, 奈津美", "creatorNameLang": "ja"}, {"creatorName": "イシカワ, ナツミ", "creatorNameLang": "ja-Kana"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2024-04-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "04.pdf", "filesize": [{"value": "1.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_2", "mimetype": "application/pdf", "size": 1200000.0, "url": {"url": "https://tbgu.repo.nii.ac.jp/record/2000043/files/04.pdf"}, "version_id": "c0c1d79d-010a-42fb-abc6-bd5ae735e168"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "黄色着色フィルム", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ColorDx CCT-HD", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "S 錐体コントラスト感度", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Yellow tinted film", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "S cone contrast sensitivity", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "若年者の黄色着色フィルム使用による錐体コントラスト感度変化", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "若年者の黄色着色フィルム使用による錐体コントラスト感度変化", "subitem_title_language": "ja"}, {"subitem_title": "Changes in cone contrast sensitivity using a yellow tinted film in young adult humans", "subitem_title_language": "en"}]}, "item_type_id": "10002", "owner": "12", "path": ["1711512520413"], "permalink_uri": "https://tbgu.repo.nii.ac.jp/records/2000043", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2024-04-02"}, "publish_date": "2024-04-02", "publish_status": "0", "recid": "2000043", "relation": {}, "relation_version_is_last": true, "title": ["若年者の黄色着色フィルム使用による錐体コントラスト感度変化"], "weko_shared_id": -1}
若年者の黄色着色フィルム使用による錐体コントラスト感度変化
https://tbgu.repo.nii.ac.jp/records/2000043
https://tbgu.repo.nii.ac.jp/records/20000435571f08a-4828-4e39-a6c0-91ea1f3e99bc
名前 / ファイル | ライセンス | アクション |
---|---|---|
04.pdf (1.2 MB)
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2024-04-02 | |||||||||||||||||
タイトル | ||||||||||||||||||
言語 | ja | |||||||||||||||||
タイトル | 若年者の黄色着色フィルム使用による錐体コントラスト感度変化 | |||||||||||||||||
タイトル | ||||||||||||||||||
言語 | en | |||||||||||||||||
タイトル | Changes in cone contrast sensitivity using a yellow tinted film in young adult humans | |||||||||||||||||
言語 | ||||||||||||||||||
言語 | jpn | |||||||||||||||||
資源タイプ | ||||||||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||||
資源タイプ | departmental bulletin paper | |||||||||||||||||
著者 |
原口, 翔太
× 原口, 翔太
× 小野, 峰子
× 石川, 奈津美
|
|||||||||||||||||
抄録 | ||||||||||||||||||
内容記述タイプ | Abstract | |||||||||||||||||
内容記述 | 【目的】黄色着色フィルム使用の有無による短(S)・中(M)・長波長感受性(L)錐体コントラスト感度の客観的な変化をColorDx CCT-HD を用いて明らかにすることを目的とした.【対象および方法】屈折異常以外の眼疾患のない10 例18 眼(20.9±0.3 歳,矯正視力1.0 以上)を対象とした.黄色着色フィルムはペーパー・インクリボンCK900L を使用し,錐体コントラスト感度はColorDx CCT-HD を用いた.黄色着色フィルムで呈示視標を覆った状態(On)と通常測定状態(Normal)で左右眼をそれぞれ測定し,ColorDx CCT-HD の測定結果であるlogCS と独自Score の平均値を比較検討した.【結果】logCS はL・M・S 錐体において,Normal でそれぞれ2.0±0.1,1.9±0.1,0.8±0.1,On で1.9±0.1,1.9±0.1,0.6±0.1 となり,L,M 錐体は有意差がみられず,S 錐体で有意に低下した.Score の結果はNormalで106.2±14.1,103.3±11.9,99.3±13.9,On では99.7±12.4,96.1±9.1,77.9±11.3 で,logCS と同様だった.【結論】ColorDx CCT-HD で黄色着色フィルム使用の有無による錐体コントラスト感度測定をした結果,S 錐体コントラスト感度の有意な低下がみられ,S 錐体活動の抑制を客観的に示すことができた. | |||||||||||||||||
言語 | ja | |||||||||||||||||
抄録 | ||||||||||||||||||
内容記述タイプ | Abstract | |||||||||||||||||
内容記述 | 【Purpose】To investigate objective changes in long (L), middle (M), and short wavelength sensitive (S) cones contrast sensitivity with and without using a yellow tinted film.【Subjects and methods】The subjects were 18 eyes (20.9±0.3 years old, corrected visual acuity of 1.0 or more in decimal) of 10 patients with no eye disease other than refractive error. The film used was a paper ink ribbon. The cone contrast sensitivity (CCS) was measured using the ColorDx CCT HD software for color vision test. We used the Landolt ring corresponding to the L, M, and S cones. The measurements were recorded with the film non-covering target (Normal) and the covering target (On). We compared the logCS values and scores of each CCS with and without the film. 【Results】Regarding the L, M, and S cones, the logCS values were 2.0 ±0.1, 1.9±0.1, and 0.8±0.1 without the film and 1.9±0.1, 1.9±0.1, and 0.6±0.1 with it. No significant difference was observed under the L and M cones. The S cone significantly reduced. The scores were 106.2±14.1,103.3±11.9, and 99.3±13.9 without the film and 99.7±12.4,96.1±9.1 and 77.9±11.3 with it, similar to the logCS values. 【Conclusion】Measurements with of CCS with the ColorDx CCT-HD showed that the sensitivity of S-CCS using the film significantly reduced in young adult humans, objectively demonstrating suppression of the S cone activity. | |||||||||||||||||
言語 | en | |||||||||||||||||
書誌情報 |
ja : 東北文化学園大学医療福祉学部リハビリテーション学科紀要 : リハビリテーション科学 en : Rehabilitation science : memoirs of the Tohoku Bunka Gakuen University Faculty of Medical Science & Welfare, Department of Rehabilitation 巻 20, 号 1, p. 13-19, 発行日 2024-03-31 |
|||||||||||||||||
出版者 | ||||||||||||||||||
言語 | ja | |||||||||||||||||
出版者 | 東北文化学園大学医療福祉学部リハビリテーション学科 | |||||||||||||||||
ISSN | ||||||||||||||||||
収録物識別子タイプ | PISSN | |||||||||||||||||
収録物識別子 | 13497197 | |||||||||||||||||
書誌レコードID | ||||||||||||||||||
収録物識別子タイプ | NCID | |||||||||||||||||
収録物識別子 | AA12032779 |